ENGINEERING DATA SHEET 065*I
RELAY - LATCH
2 PDT, 0.5 AMP

Polarized, latching hermetically sealed relay
Contact arrangement 2 PDT
Alternative pulsing of latch or reset coil will transfer contacts
Meets the requirements of MIL-R-39016/47
CECC16101-026

PRINCIPLE TECHNICAL CHARACTERISTICS


Contacts rated at

0.5 Amp / 28 Vdc
Weight 2 grams max
Dimensions of case 14.6mm x 8.8mm x 4.29mm max
Hermetically sealed, corrosion protected metal can.

CONTACT ELECTRICAL CHARACTERISTICS
Minimum
operating cycles
Contact rating per
pole and load type
Load Current in Amps
@28Vdc
100,000 cycles
100,000 cycles
1,000,000 cycles
resistive load
inductive load (200mH)
low level (30ľA/30mV)
0.5
0.1
-
100 cycles
resistive overload 1


  Featuring LEACH© power and control solutions
  www.esterline.com
AMERICAS
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622


Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
EUROPE
2 Rue Goethe
57430 Sarralbe
France


Tel: (33) 3 87 97 31 01
Fax: (33) 3 87 97 96 86
ASIA
Units 602-603 6/F Lakeside 1
No.8 Science Park West Avenue
Phase Two, Hong Kong Science Park
Pak Shek Kok, Tai Po, N.T.
Hong Kong
Tel: (852) 2 191 3830
Fax: (852) 2 389 5803

Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component.
Date of issue: 9/10 - 1 - Page 1 of 4