NUMBERING SYSTEM
SERIES THLOR
                                               THLOR 72   H   4   ZWY
Basic series designation__________________________|   |   |   |    |
Operating voltage (24,48,72,110)______________________|   |   |    |
1-Mounting Styles (A,B,C,D,J,K,H)_________________________|   |    |
2-Terminal Types(1,2,4,8)_____________________________________|    |
3-Coding keys for H mounting style_________________________________|

NOTES
  1. Relays with B, D mounting styles and terminal type 4 are compatible with socket SF402CE40E.
  2. Relays with H mounting style are compatible with socket SF402-1F.
  3. Isolation spacer pads for PCB mounting available on request.
  4. For other mounting styles or terminal types or coding, please contact factory.

CODING CHART FOR H MOUNTING
Operating voltage 24 V 48 V 72 V 110 V
Coding ZUY ZVY ZWY ZXY

TIMING PROGRAMMATION
Timing range Terminals to connect Timing delay Timing range Terminals to connect Timing delay
1
a1-b1
connected
b3-a2
b3-a3
b3-a4
b3-b4
b3-c4
b3-c3
b3-c2
b3-b2
0.25 s
0.5 s
1 s
2 s
4 s
8 s
16 s
32 s
2
a1-b1
non connected
b3-a2
b3-a3
b3-a4
b3-b4
b3-c4
b3-c3
b3-c2
b3-b2
0.25 mn
0.5 mn
1 mn
2 mn
4 mn
8 mn
16 mn
32 mn

Time delay options from 0.25 to 63.75 seconds
Time delay options from 0.25 to 63.75 seconds
Intermediate time delay may be obtained by multiple wiring.
Example: for 12 s = 8 s + 4 s, connect C3 and C4 to B3.
Date of issue: 4/06 - 73 - Page 4 of 4