ENGINEERING DATA SHEET SERIES THLOR
RAILWAY TIME DELAY RELAY
PROGRAMMABLE TIMER WITH
SOLID STATE OUTPUT


Time delay on release in a hermetically sealed package

Time delay programmable by wiring
Output characteristics 1 solid state output
Supply Direct current

PRINCIPLE TECHNICAL CHARACTERISTICS

Contact rating 0.01 to 0.25 Amp at nominal voltage
Weight < 80 grams
Dimensions of can without hardware 26mm x 25.7mm x 26mm max
Tin plated, hermetically sealed metal can.

GENERAL CHARACTERISTICS
Operating temperature -25°C to +70°C
Dielectric strength at sea level
All terminals to ground 1500 Vrms / 50 Hz
Initial insulation resistance at 500 Vdc >1000 M W
Sinusoidal vibration 10 G / 10 to 2000 Hz
Shock 30 G / 11 ± 1 ms
Timing accuracy over termperature range ± 10%
Protection against reverse polarity yes
Esterline-Leach International
  www.leachintl.com
North America
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622 USA

Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
Europe, SA
2 Rue Goethe
57430 Sarralbe
France

Tel: (33) 3 87 97 98 97
Fax: (33) 3 87 97 84 04
Asia-Pacific Ltd.
20/F Shing Hing Commercial Bldg.
21-27 Wing Kut Street
Central, Hong Kong

Tel: (852) 2 191 2886
Fax: (852) 2 389 5803
Data sheets are for initial product selection and comparison. Contact Leach International prior to choosing a component.
Date of issue: 4/06 - 70 - Page 1 of 4