ENGINEERING DATA SHEET SERIES F***M06 and M07
RAILWAY RELAY WITH
ATTRACT AND HOLD COIL

2 PDT, 1 AMP / 72VDC



GENERAL

The hermetically sealed relays for railway application series F470, F670, FD*70, F*70S1 and F670S2 may be equiped with attract and hold coils.

For all switching and environmental characteristics, see the technical data sheet of the basic relay.

The following pages show terminal and schematic arrangements as well as coil characteristics.

TYPICAL APPLICATIONS

  • Safety delay on release
  • Lost control operation
  • Energy saving
    (See application note n°006)

  • CONTACT ELECTRICAL CHARACTERISTICS
    Nominal contact voltage (Vdc) Contact rating in Amps Level Minimum
    operating cycles
    Simple break-make Double break-make
    resistive
    load
    inductive
    load (L/R=30ms)
    resistive
    load
    inductive
    load (L/R=30ms)
    72 V
    5 £ U £ 90 V
    15 £ U £ 35 V
    35 < U £ 90 V
    90 < U £ 140 V
    1
    1 to 20mA
    -
    -
    0.6
    -
    10 mA to 1.50 Amps
    10 mA to 0.50 Amps
    10 mA to 0.35 Amps
    3
    -
    -
    -
    -
    1.2
    -
    10 mA to 2.50 Amps
    10 mA to 1.00 Amps
    10 mA to 0.70 Amps
    High level
    Low level
    High level
    High level
    High level
    1,000,000 cycles
    2,000,000 cycles
    2,000,000 cycles
    2,000,000 cycles
    2,000,000 cycles
    Life expectancy for DC loads other than 72Vdc: See application note n°003 and n°004
    Esterline-Leach International
      www.leachintl.com
    North America
    6900 Orangethorpe Ave.
    P.O. Box 5032
    Buena Park, CA 90622 USA

    Tel: (01) 714-736-7599
    Fax: (01) 714-670-1145
    Europe, SA
    2 Rue Goethe
    57430 Sarralbe
    France

    Tel: (33) 3 87 97 98 97
    Fax: (33) 3 87 97 84 04
    Asia-Pacific Ltd.
    20/F Shing Hing Commercial Bldg.
    21-27 Wing Kut Street
    Central, Hong Kong

    Tel: (852) 2 191 2886
    Fax: (852) 2 389 5803
    Data sheets are for initial product selection and comparison. Contact Leach International prior to choosing a component.
    Date of issue: 4/06 - 54 - Page 1 of 4