ENGINEERING DATA SHEET SERIES F670S2
RAILWAY RELAY
2 PDT-DB-DM+2PDT, 3 AMP / 72VDC


Polarized, non latching, hermetically sealed relay
Contact arrangement 2 PDT-DB-DM + 2PDT
Coil supply Direct current

PRINCIPLE TECHNICAL CHARACTERISTICS

Contact rating (2 PDT-DB-DM) 72 Vdc / 3 Amp
Contact rating (2 PDT) 72 Vdc / 1 Amp
Weight < 110 grams
Dimensions of can without hardware 26.7mm x 25.7mm x 37.7mm max
Balanced-force design.
Tin plated, hermetically sealed metal can.
Non-overlapping contact arrangement, see note 5 page 4.

CONTACT ELECTRICAL CHARACTERISTICS
Nominal contact voltage (Vdc) Contact rating in Amps Level Minimum
operating cycles
Simple break Double break
resistive
load
inductive
load (L/R=30ms)
resistive
load
inductive
load (L/R=30ms)
72 V
5 £ U £ 90 V
15 £ U £ 35 V
35 < U £ 90 V
90 < U £ 140 V
1
1 to 20mA
-
-
-
0.6
-
10 mA to 1.50 Amps
10 mA to 0.50 Amps
10 mA to 0.35 Amps
3
-
-
-
-
1.2
-
10 mA to 2.50 Amps
10 mA to 1.00 Amps
10 mA to 0.70 Amps
High level
Low level
High level
High level
High level
1,000,000 cycles
2,000,000 cycles
2,000,000 cycles
2,000,000 cycles
2,000,000 cycles
Life expectancy for DC loads other than 72Vdc: See application note n°003 and n°004
Esterline-Leach International
  www.leachintl.com
North America
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622 USA

Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
Europe, SA
2 Rue Goethe
57430 Sarralbe
France

Tel: (33) 3 87 97 98 97
Fax: (33) 3 87 97 84 04
Asia-Pacific Ltd.
20/F Shing Hing Commercial Bldg.
21-27 Wing Kut Street
Central, Hong Kong

Tel: (852) 2 191 2886
Fax: (852) 2 389 5803
Data sheets are for initial product selection and comparison. Contact Leach International prior to choosing a component.
Date of issue: 4/06 - 34 - Page 1 of 4