ENGINEERING DATA SHEET
SERIES FD670
RAILWAY RELAY
3 PDT-DB-DM, 3 AMP / 72VDC
APPLICATION NOTES:
001
004
007
APPLICABLE SOCKET:
SFD600CE40E
SF600-2F
Polarized, non latching, hermetically sealed relay
Contact arrangement
3 PDT-DB-DM
Coil supply
Direct current
PRINCIPLE TECHNICAL CHARACTERISTICS
Contact rating
72 Vdc / 3 Amp
Weight
< 110 grams
Dimensions of can without hardware
26.7mm x 25.7mm x 37.7mm max
Balanced-force design.
Tin plated, hermetically sealed metal can.
Non-overlapping contact arrangement, see note 5 page 4.
CONTACT ELECTRICAL CHARACTERISTICS
Nominal contact
voltage (Vdc)
Contact rating in Amps
Level
Minimum
operating cycles
resistive load
inductive load (L/R=30ms)
72 V
15
£
U
£
35 V
35
<
U
£
90 V
90
<
U
£
140 V
3
-
-
-
1.2
10 mA to 2.50 Amps
10 mA to 1.00 Amps
10 mA to 0.70 Amps
High level
High level
High level
High level
1,000,000 cycles
2,000,000 cycles
2,000,000 cycles
2,000,000 cycles
Life expectancy for DC loads other than 72Vdc: See application note n°004.
www.leachintl.com
North America
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622 USA
Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
Europe, SA
2 Rue Goethe
57430 Sarralbe
France
Tel: (33) 3 87 97 98 97
Fax: (33) 3 87 97 84 04
Asia-Pacific Ltd.
20/F Shing Hing Commercial Bldg.
21-27 Wing Kut Street
Central, Hong Kong
Tel: (852) 2 191 2886
Fax: (852) 2 389 5803
Data sheets are for initial product selection and comparison. Contact Leach International prior to choosing a component.
Date of issue: 4/06
- 50 -