ENGINEERING DATA SHEET SERIES F370
RAILWAY RELAY
2 PDT, 1 AMP / 72VDC


Polarized, non latching, hermetically sealed relay
Contact arrangement 2 PDT
Coil supply Direct current
Meets the requiements of MIL-R-6106
CEECC16101-018
NF F 62-002-2

PRINCIPLE TECHNICAL CHARACTERISTICS


Contact rating

72 Vdc / 1 Amp
Weight < 40 grams
Dimensions of can without hardware 26mm x 25.7mm x 13.3mm max
Balanced-force design.
Tin plated, hermetically sealed metal can.
Non-overlapping contact arrangement, see note 4 page 4.

CONTACT ELECTRICAL CHARACTERISTICS
Nominal contact
voltage (Vdc)
Contact rating in Amps Level Minimum
operating cycles
resistive load inductive load (L/R=30ms)
72 V
5 £ U £ 90 V
15 £ U £ 35 V
35 < U £ 90 V
90 < U £ 140 V
1
1 to 20mA
-
-
-
0.6
-
10 mA to 1.50 Amps
10 mA to 0.50 Amps
10 mA to 0.35 Amps
High level
Low level 
High level
High level
High level
1,000,000 cycles
2,000,000 cycles
2,000,000 cycles
2,000,000 cycles
2,000,000 cycles
Life expectancy for DC loads other than 72Vdc: See application note n°003


  Featuring LEACH© power and control solutions
  www.esterline.com
AMERICAS
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622 USA


Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
EUROPE
2 Rue Goethe
57430 Sarralbe
France


Tel: (33) 3 87 97 31 01
Fax: (33) 3 87 97 96 86
ASIA
Units 602-603 6/F Lakeside 1
No.8 Science Park West Avenue
Phase Two, Hong Kong Science Park
Pak Shek Kok, Tai Po, N.T.
Hong Kong
Tel: (852) 2 191 3830
Fax: (852) 2 389 5803

Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component.
Date of issue: 4/06 - 9 - Page 1 of 4