ELECTRICAL CHARACTERISTICS EPM-110 SERIES
Parameter Symbol Conditions Limits Unit Notes
Min. Max.
INPUT SPECIFICATIONS
BIAS ON voltage Vib
4.5 5.5 V (1,2)
BIAS ON current Iib
- 75 mA (3)
RECEIVE voltage high Vihr
2.4 - V
RECEIVE voltage low Vilr
- 0.8 V
RECEIVE current high Iihr Vihr = 2.4 V - 50 µA
RECEIVE current low Iilr Vilr = 0.4 V - -10 µA
Transient voltage Vt Pulse width = 12.5 msec
max. per DO-160D
- +50 V (4)
Spikes Vs Pulse width = 10 msec
max. per DO-160D
-600 +600 V (4)
OUTPUT SPECIFICATIONS
Load Current Il
0 100 %rated I (5)
ON state voltage drop Vld
- 200 mV (6)
OFF state line voltage Vl
- 70 V (7)
Leakage current Ill
- 3 mA (8)
Maximum let through current Itr
110 135 %rated I
Dielectric withstanding voltage Vdw
- 500 VRMS (9)
Insulation resistance Rins
100
Mohm (10)
TRANSMIT voltage high Voht Iot = -4 mA Vib*0.8
V
TRANSMIT voltage low Volt Iot = 4 mA
0.8 V
TRANSMIT voltage rise time Tort CL = 15 pf
3 ns
TRANSMIT voltage fall time Toft CL = 15 pf
3 ns
Notes:
(1) BIAS voltage must be a step function.
(2) No reverse polarity protection.
(3) BIAS voltage is +5.0Vdc.
(4) The requirement apply only to the 28Vdc power line.
(5) Load current is subject to thermal derating.
(6) At load current li = 100% rated value.

(7) Reverse polarity is not blocked and may damage the SSPC.
(8) At Vi = 28Vdc, case temperature = 100°C.
(9) 60 Hz, electrification time 10s, tested between each isolated section in turn groups (1,2 and 3), at sea level, ambient temperature, with the other two isolated sections shorted together.
(10) 500Vdc, ±10.
Date of issue: 2/07 - 9 - Page 3 of 6