ELECTRICAL CHARACTERISTICS (VOLTAGE STATUS) P150 SERIES
Typical values are at 25 ± 5° C
INPUT
DEVICE WITH VOLTAGE STATUS LIMITS UNIT NOTES
Parameter Symbol CONDITIONS
-55°C to +105°C (1)
MIN MAX

Logic supply voltage VCC
4.5 5.5 Vdc
CONTROL voltage high VIH
2.0
Vdc
CONTROL voltage low VIL

0.8 Vdc
Transient
Pulse width = 12.5 msec max. per MIL-STD-704D
+50 Vdc 2
Spikes
Pulse width = 10 µsec max. per MIL-STD-704D -600 +600 Vdc 2
REQUIREMENTS
28 Vdc initialization spike voltage
During of output spike at 50% amplitude shall be 100µsec maximum
5 VPR
5 Vdc initialization control
Vline = 28 Vdc, Vcontrol = 0 Vdc, Vbias = 0 to 5 Vdc, rated at <1 msec


3
Logic supply current ICC VCC=5.5 Vdc
50 mA 4
Load current continuous ILOAD

100 %I
"ON" state voltage drop VO

200 mV 5
Leakage current IL

1 mA
STATUS & TRIP voltage high VOH IOH=5mA 2.4
Vdc
STATUS & TRIP voltage low VOL IOL=1mA
0.4 Vdc
CONTROL current high IIH VI=2.4 Vdc
50 µA
CONTROL current low IIL VI=0.4 Vdc
10 µA
Output "ON" sense voltage VON See Timing Diagram (Voltage Status) 30 70 % 5,6,7
Notes:
1. Unless specified otherwise, test conditions shall be at Vcc=5.0±0.25Vdc and Vline=28±0.5Vdc. The design shall be capable of meeting all requirements with Vcc=4.5 to 5.5Vdc.
2. The transient and spike requirements apply only to the 28Vdc power lines.
3. The device output shall remain off when 5V bias is raised from 0 to 5Vdc.
4. Without any load connected to the STATUS or TRIP outputs.
5. At 100% rated current.
6. Rated resistive load; measurements taken between 10% and 90% points.
7. Percent of actual applied Vline.
Date of issue: 4/10 - 12 - Page 4 of 6