Typical values are at 25 ± 5° C INPUT |
DEVICE WITH VOLTAGE STATUS |
LIMITS |
UNIT |
NOTES |
| Parameter |
Symbol |
CONDITIONS -55°C to +105°C (1) |
MIN |
MAX |
|
|
| Logic supply voltage |
VCC |
|
4.5 |
5.5 |
Vdc |
|
| CONTROL voltage high |
VIH |
|
2.0 |
|
Vdc |
|
| CONTROL voltage low |
VIL |
|
|
0.8 |
Vdc |
|
| Transient |
|
Pulse width = 12.5 msec max. per MIL-STD-704D |
|
+50 |
Vdc |
2 |
| Spikes |
|
Pulse width = 10 µsec max. per MIL-STD-704D |
-600 |
+600 |
Vdc |
2 |
| REQUIREMENTS |
| 28 Vdc initialization spike voltage |
|
During of output spike at 50% amplitude shall be 100µsec maximum |
|
5 |
VPR |
|
| 5 Vdc initialization control |
|
Vline = 28 Vdc, Vcontrol = 0 Vdc, Vbias = 0 to 5 Vdc, rated at <1 msec |
|
|
|
3 |
| Logic supply current |
ICC |
VCC=5.5 Vdc |
|
50 |
mA |
4 |
| Load current continuous |
ILOAD |
|
|
100 |
%I |
|
| "ON" state voltage drop |
VO |
|
|
200 |
mV |
5 |
| Leakage current |
IL |
|
|
1 |
mA |
|
| STATUS & TRIP voltage high |
VOH |
IOH=5mA |
2.4 |
|
Vdc |
|
| STATUS & TRIP voltage low |
VOL |
IOL=1mA |
|
0.4 |
Vdc |
|
| CONTROL current high |
IIH |
VI=2.4 Vdc |
|
50 |
µA |
|
| CONTROL current low |
IIL |
VI=0.4 Vdc |
|
10 |
µA |
|
| Output "ON" sense voltage |
VON |
See Timing Diagram (Voltage Status) |
30 |
70 |
% |
5,6,7 |