ENGINEERING DATA SHEET SERIES 1811, 1816, 1860, 1866
HERMETICALLY SEALED LIMIT SWITCH
1-2 PDT, 5 AMP


- 1811 series
 
  * Certification  _ AIR 8461
 
  * Letter _ _ _ _ | 40874 STPA
                   | of 22/10/63
 
- 1816-1860-1866 series
 
  * Issued from 1811
      
Meets the requirements of AIR 8461
AIR 9461
AIR 0713

PRINCIPLE TECHNICAL CHARACTERISTICS

Hermetically sealed plunger switch (quick make/break)

Simple push button operation (axial command only)

Operated by roller-ended plunger (compatible with oblique actuation forces)

Transfer of movement via metal bellows

Actuation force internally adjusted by rotation within the collar, or

Actuation force management by locknuts and positioning washers within the smooth housing

Weight
see P/N chart
55 to 75 grams ±5%
Nickel plated brass frame
Switch terminals soldered to a hermetic connector

CONTACT ELECTRICAL CHARACTERISTICS
Load type Electrical ratings
30Vdc 115Vac / 400Hz
Nominal
rating
(Amps)
Overload
rating
(Amps)
Nominal
rating
(Amps)
Overload
rating
(Amps)
Resistive 5 7.5 5 7.5
Inductive (L/R=5ms) 4 5 4 5
Lamp 3 5 3 5


  Featuring LEACH© power and control solutions
  www.esterline.com
AMERICAS
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622


Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
EUROPE
2 Rue Goethe
57430 Sarralbe
France


Tel: (33) 3 87 97 31 01
Fax: (33) 3 87 97 96 86
ASIA
Units 602-603 6/F Lakeside 1
No.8 Science Park West Avenue
Phase Two, Hong Kong Science Park
Pak Shek Kok, Tai Po, N.T.
Hong Kong
Tel: (852) 2 191 3830
Fax: (852) 2 389 5803

Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component.
Date of issue: 4/06 - 16 - Page 1 of 4