GENERAL CHARACTERISTICS SERIES 2008, 2012, 20008, 20012
Temperature range -55°C to +80°C
Minimum operating cycles (life) at rated load 50,000 cycles
Dielectric strength at sea level 500 Vrms
Dielectric strength at max altitude 300 Vrms
Insulation resistance at 500 Vdc 100 M W
Sinusoidal vibration 10G / 20 to 2000 Hz
Shock 50G / 11 ms
Contact voltage drop, initial value 120 mV

NOTES
Admissible limits curve for angular commande
OTAN CODES



Type                         N.N.O.

2008...................5930 14 282 8543

2012...................

20008..................5930 14 282 8544

20012..................5930 14 428 4661

Date of issue: 4/06 - 27 - Page 4 of 4