STANDARD FEATURES SERIES L302
2. SWITCH CONFIGURATION
A. 1 PDT
B. 2 PDT
C. 3 PDT
D. 4 PDT
E. 1 PDT
F. 2 PDT
G. 3 PDT
H. 4 PDT
J. Indicator
3. MECHANICAL ACTION

0. Indicator
1. Momentary
2. Alternate
4. CAP PROTRUSION

0. 3 mm (travel 4.5mm)
1. 7 mm (travel 6mm)
No travel on indicator
5. CONNECTOR

0. No
1. Yes
6. LAMP CIRCUIT

1. Horizontal split ground
2. Vertical split ground
3. Common ground
7. LAMP TYPE

1. 28 V, 24 mA, 0.15 MSCd
2. 5 V, 60 mA, 0.05 MSCd
3. 6 V, 40 mA, 0.04 MSCd
4. 12 V, 30 mA, 0.10 MSCd
Other lamps and leds available
8. OPTIONS

0. None
1. Flip guard
2. Drip shroud
3. Mounting spacer
4. Barrier

9. LENS CONFIGURATION
A B C D E F G H
1
1
2
1 2
1 2
3
1
3 2
1 2
3
1 2
3
1 2
4 3

10. LEGEND TYPE
  1. Colored characters not visible until illuminated, opaque black background (hidden legend)
  2. Opaque black characters on black background (hidden legend). Background shows color when illuminated
  3. Opaque black characters visible at all times on white background. Background shows color when illuminated
  4. White characters visible at all times on opaque black background. Characters show color when illuminated
  5. Opaque black characters and visible colored background. Background shows color when illuminated
  6. Opaque white characters and visible colored background. Background shows color when illuminated
  7. No characters. Plain colored filter which shows color when illuminated
  8. No characters. Plain white filter which shows color when illuminated
  9. Specific request

11. FILTER COLOR 12. LEGEND
0. Amber
1. Blue
2. Green
3. Red
4. White
5. Yellow
NVG compatibility available
Add legend after the switchlight code using commas (,) between rows & slash (/) between splits. Standard characters are to DIN 1451 type 4. Specify legend type, color and legend in the numerical order as specified in section 9.
Date of issue: 4/06 - 7 - Page 3 of 4