ENGINEERING DATA SHEET SERIES CSHPB
HALL EFFECT CURRENT SENSOR
FOR BATTERY BUS DIRECT AND RETURN PROTECTION

FEATURES AND CHARACTERISTICS

  • Electronic module in association with a contactor to provide bi-directional protection adapted to current flow direction.
  • Designed for direct mounting on bus bar contactors.
  • Provide an I2t trip law, with accelerated trip time at currents higher than 10 In in the direction battery to bus. In the reversed direction, trip current and law may be defined at different level.
  • No voltage drop in protected line.
  • Trip status provided by an internal latching device.
  • Override input to avoid inadvertent trip during start process.
  • IBIT circuit for high reliability operation.
  • Weight: 110 grams ± 5%.
  • Temperature range: -50°C To +85°C

  • GENERAL ELECTRICAL SPECIFICATIONS
    Supply voltage according to MIL Std 704 16 to 32 Vdc
    Current supply at 28 Vdc 30 mA max + contactor coil supply
    Cold weather supply voltage operation 10.5 Vdc
    Low voltage protection by immediate trip < 9 V ± 10%
    Output current 1 amp permanent 6 Amps inrush (30ms)
    Dielectric strength (All secondary terminal to ground) 1000 Vdc
    Insulation resistance (All secondary terminal to ground) 100 MW at 50 Vdc
    Esterline-Leach International
      www.leachintl.com
    North America
    6900 Orangethorpe Ave.
    P.O. Box 5032
    Buena Park, CA 90622 USA

    Tel: (01) 714-736-7599
    Fax: (01) 714-670-1145
    Europe, SA
    2 Rue Goethe
    57430 Sarralbe
    France

    Tel: (33) 3 87 97 98 97
    Fax: (33) 3 87 97 84 04
    Asia-Pacific Ltd.
    20/F Shing Hing Commercial Bldg.
    21-27 Wing Kut Street
    Central, Hong Kong

    Tel: (852) 2 191 2886
    Fax: (852) 2 389 5803
    Data sheets are for initial product selection and comparison. Contact Leach International prior to choosing a component.
    Date of issue: 3/06 - 30 - Page 1 of 3