ENVIRONMENTAL CONDITIONS SERIES CSHM
Vibrations
- Sinusoidal per MIL Std 202 Method 204 : 20-2000 Hz
- Random 10-2000 Hz

10 G
0.15 g2/Hz
Shock: Structure per MIL Std 202 method 213 30 G
Salt Spray per MIL Std 202 method 101 96 H
Humidity: per MIL Std 202 method 106 - HR 95% 240H
Altitude 45000 ft max.
Voltage spikes: DO160 section 17 category A
Audio frequency conducted susceptibity: DO160 section 18 category Z
Induced signals: DO160 section 19 category Z
Radio frequency: DO160 section 20 category W
Lightning: DO160 section 22 category B2F2. (B4F4 with additional)

MOUNTING SCHEMATIC AND WIRING DIAGRAM
pluginspage="http://www.autodesk.com/products/whip" width=330 height=350>

NUMBERING SYSTEM
 CSHM 800
  |    |-------Maximum current in Amps (existing standard 400 and 800)
  |
  |------------Basic family current sensor for measurement
      

Date of issue: 3/06 - 29 - Page 2 of 2