ENGINEERING DATA SHEET
|
SERIES
V610
AC POWER MONITORING SENSOR 2 PDT OR 3 PDT, 10 AMP
|
|
|
|
FEATURES AND CHARACTERISTICS
|
- Contacts: 2 PDT or 3 PDT
- Hermetically sealed
- Weight: 27 oz. max.
- Sensing range: 90 to 150 Vrms
- Temperature range: -55°C to +125° C
- Custom units available
|
|
GENERAL SPECIFICATIONS
| Input voltage |
90 to 150 Vrms, line
to neutral
3 phase WYE |
| Input
frequency |
44 to 480 Hz |
| Pick-up time delay |
50 to 10 ms ±10% |
| Drop-out time delay |
50 to 10 ms ±10% |
| Sensing accuracy |
Voltage ±2% to ±10%
Frequency: ±2%
based on a true sinusoidal input wave
form |
| Phase sequence sensing |
ABC |
| Configuration and contact rating |
2 PDT, 2 Amps or 10 Amps; 3 PDT, 10
Amps |
| Temperature range |
-55° C to + 125° C |
| Maximum operating current per phase |
75 milliamperes RMS |
| Voltage transients |
PER MIL-STD-704A, CAT.B |
| Operating cycles at rated resistive
load |
100,000 cycles min. |
| Vibration |
0.06" D.A., 5 to 80 Hz, 20 g, 80 to 2000
Hz |
| Shock |
50 g, 11 ± 1 ms, 1/2 sine, 3 axes |
| Acceleration |
20 g in any axis |
| Finish |
Tin Plate PER MIL-T-10727 |
| Detailed ordering information |
See next page |
|