NUMBERING SYSTEM
|
SERIES P510
|
P510 - J - B A
Basic series designation: AC sequence sensor, P510 can size________| | | |
1-Output Configuration: J series relay, 2 PDT, 10 Amps Res, @28 Vdc _____| | |
3-Temperature range: -55° C to +125° C_______________________________________| |
4-Mounting Style And Terminals: Style A_________________________________________|
|
1. SERIES NUMBER
Indicates physical dimensions and weight
P510 1.53 x 1.53 x 2.34 wt 10 oz. max
2. OUTPUT CONFIGURATION, CONTACT RATINGS
MIL-PRF-83536 TYPE
J 2 PDT, Leach series J relay, 10 Amp resistive,
@28 Vdc and 115 Vac, 400 Hz
K 4 PDT, Leach series K relay, 10 Amp resistive,
@28 Vdc and 115 Vac, 400 Hz
NOTE: For additional data on contact ratings, contact the factory.
|
3. TEMPERATURE RANGE AND ACCURACY
Code Letter A B
|
Temp, Range -55° To +85°C -55° To +125°C
|
4. MOUNTING STYLES AND TERMINALS
See next page
|
|
NOTES
1.
|
Operating Mode
The output relay energizes when the phase sequence is ABC and De-energizes for all
other phase sequences; Open neutral or loss of voltage of any phase.
|
2.
|
Dielectric Strength
Input to case
2 Amp contacts
contacts to case
Across open contacts
10 Amp contacts
contacts to case
Across open contacts
|
1,000 Vrms
1,000 Vrms
500 Vrms
1,250 Vrms
1,250 Vrms
|
3.
|
Contact factory for phase sensor requirements not covered in this publication.
|
|
|