ENGINEERING DATA SHEET SERIES V310
AC OVERVOLTAGE SENSOR
2PDT OR 4PDT, 10 AMP


APPLICABLE SOCKETS:
SO-1021-7127/7126
FEATURES AND CHARACTERISTICS
  • Contacts: 2 PDT or 4 PDT
  • Hermetically sealed
  • Weight: 10 oz. max.
  • Sensing range: 90 to 124 Vac
  • Temperature range: -55°C to +125° C
  • Custom units available
  • GENERAL SPECIFICATIONS
    Input voltage 90 to 124 Vac, line to neutral
    400 Hz ± 20 Hz, 3 phase WYE
    Pick-up time 50 ms, max.
    Drop-out time 50 ms, max.
    Sensing accuracy ±2% through ±10%
    based on a true sinusoidal input wave form
    Configuration and contact rating 2 PDT, 2 Amps or 10 Amps;
    4 PDT, 10 Amps
    Temperature range -55° C to + 125° C
    Maximum operating current 75 milliamperes
    Voltage transients PER MIL-STD-704A, CAT.B
    Operating cycles at rated resistive load 100,000 cycles min.
    Vibration 0.06" D.A., 5 to 80 Hz, 20 g, 80 to 2000 Hz
    Shock 50 g, 11 ± 1 ms, 1/2 sine, 3 axes
    Acceleration 20 g in any axis
    Finish Tin Plate PER MIL-T-10727
    Detailed ordering information See next page
    Esterline-Leach International
      www.leachintl.com
    North America
    6900 Orangethorpe Ave.
    P.O. Box 5032
    Buena Park, CA 90622 USA

    Tel: (01) 714-736-7599
    Fax: (01) 714-670-1145
    Europe, SA
    2 Rue Goethe
    57430 Sarralbe
    France

    Tel: (33) 3 87 97 98 97
    Fax: (33) 3 87 97 84 04
    Asia-Pacific Ltd.
    20/F Shing Hing Commercial Bldg.
    21-27 Wing Kut Street
    Central, Hong Kong

    Tel: (852) 2 191 2886
    Fax: (852) 2 389 5803
    Data sheets are for initial product selection and comparison. Contact Leach International prior to choosing a component.
    Date of issue: 3/06 - 1 - Page 1 of 3