ENGINEERING DATA SHEET
|
SERIES
V210
AC UNDERVOLTAGE SENSOR 2PDT OR 4PDT, 10 AMP
|
|
APPLICABLE SOCKETS:
SO-1021-7127/7126
|
FEATURES AND CHARACTERISTICS
|
- Contacts: 2 PDT or 4 PDT
- Hermetically sealed
- Weight: 10 oz. max.
- Sensing range: 90 to 124 Vac
- Temperature range: -55°C to +125° C
- Custom units available
|
|
GENERAL SPECIFICATIONS
| Input voltage |
90 to 124 Vac, line to
neutral
400 Hz ± 20 Hz, 3 phase
WYE |
| Pick-up time |
50 ms, max. |
| Drop-out time |
50 ms, max. |
| Sensing accuracy |
±2% through ±10%
based on a true sinusoidal input wave
form |
| Configuration and contact rating |
2 PDT, 2 Amps or 10 Amps;
4 PDT, 10 Amps |
| Temperature range |
-55° C to + 125° C |
| Maximum operating current |
75 milliamperes |
| Voltage transients |
PER MIL-STD-704A, CAT.B |
| Operating cycles at rated resistive
load |
100,000 cycles min. |
| Vibration |
0.06" D.A., 5 to 80 Hz, 20 g, 80 to 2000
Hz |
| Shock |
50 g, 11 ± 1 ms, 1/2 sine, 3 axes |
| Acceleration |
20 g in any axis |
| Finish |
Tin Plate PER MIL-T-10727 |
| Detailed ordering information |
See next page |
|