NUMBERING SYSTEM
|
SERIES V110
|
Options
V110 - K - 016 - C A
Basic series designation: DC voltage sensor, V110 can size ________| | | | |
1-Output Configuration: K series relay, 4 PDT, 10 Amps Res, @28 Vdc _____| | | |
2-Trip point: 16 Vdc _________________________________________________________| | |
3-Temperature And Accuracy: -55° C to +85° C, ±10% ________________________________| |
4-Mounting Style And Terminals: Style A ______________________________________________|
|
1. SERIES NUMBER
Indicates physical dimensions and weight
V110 1.53 x 1.53 x 2.34 wt 10 oz. max
2. OUTPUT CONFIGURATION, CONTACT RATINGS
MIL-PRF-83536 TYPE
J 2 PDT, Leach series J relay, 10 Amp resistive,
@28 Vdc and 115 Vac, 400 Hz
K 4 PDT, Leach series K relay, 10 Amp resistive,
@28 Vdc and 115 Vac, 400 Hz
NOTE: For additional data on contact ratings, contact the factory.
|
3. VOLTAGE TRIP POINT
Sensing range: 1 Vdc to 50 Vdc
Specify trip point within indicated sensing range, specify by using three digits, e.g.
Trip Point: 16 Vdc
Specify: 016
4. TEMPERATURE RANGE AND ACCURACY
Code Letter A B C D E
|
Temp, Range -55° To +85°C -55° To +85°C -55° To +85°C -55° To +125°C -55° To +125°C
|
Trip Point Accuracy ±2% ±5% ±10% ±5% ±10%
|
5. MOUNTING STYLES AND TERMINALS
See next page
|
|
NOTES
1.
|
Operating Mode
The output relay energizes when the voltage is above the trip
point and de-energizes when the voltage drops below the trip point.
|
2.
|
Dielectric Strength
Input to case
2 Amp contacts
contacts to case
Across open contacts
10 Amp contacts
contacts to case
Across open contacts
|
1,000 Vrms
1,000 Vrms
500 Vrms
1,250 Vrms
1,250 Vrms
|
3.
|
Hysteresis
Units have a typical hysteresis of 0.5% to eliminate cycling due to small changes
in voltage at the trip point.
|
4.
|
Contact factory for voltage sensor requirements not covered in this publication.
|
|
|