ELECTRICAL SPECIFICATION TDH-8070/8071
Input (Control) Parameters
Timing:
a. Operation, Time Delay on
b. Method
c. Range
d. Accuracy

Release
Fixed Period
0.1 to 600 Seconds [6]
±10% [1]
Recycle Time 50 ms, Max [5]
Operations: (X1-X2)
a. Input & Control Voltage
b. Operating Current
c. Control Current

20-30 Vdc
150 mA, Max @ 25° C
15 mA, Max @ 25° C
Transients:
a. Positive, MIL-STD-704A, Figure9, Limit 1
b. Spike, MIL-STD-704A, 0-10 µs
c. Self-Generated
d. Susceptibility

+80 Volts Max
±600 Volts Max
±50 Volts Max
+80; -600 Volts Max
Electromagnetic Interference Per MIL-STD-461A Class 1D [3]
Power Loss 500 Microseconds [2]

Output (Load) Parameters
Contact Form
Contact Rating:
a. Resistive
b. Inductive
c. Motor
d. Lamp
2 PDT

10 Amperes
8 Amperes
4 Amperes
2 Amperes
Dielectric Strength:
a. @ Sea Level, 60 Hz
b. @ 80,000 ft., 60 Hz

1000 Vrms [4]
350 Vrms
Insulation Resistance @ 500 Vdc 1000 M W [4]

GENERAL CHARACTERISTICS
Ambient Temperatures Range:
a. Operating
b. Non-Operating

-55 to +125° C
-65 to +125° C
Vibration:
a. Sinusoidal, 10-3000 Hz 30 G
b. Random: 50-2000 Hz, MIL-STD-810 0.4 G2/Hz
Shock @ 6 ± 1 MS, 1/2 Sine, 3 Axis 100 G
Acceleration, in any Axis 15 G
Life at Rated Resistive Load; Minimum 100,000 operations

NUMBERING SYSTEM
Plug-in Terminal          Solder Hook Terminal
TDH-8070 - 1001   P       TDH-8071 - 1001  S
   |         |    |          |        |    | 
   1         3    4          1        3    4
M83726/29 - 1001  P       M83726/29 - 1001 S
   |   |     |    |          |   |     |   |     
   1   2     3    4          1   2     3   4     

              P = Plug-in terminal.
              S = Solder hook terminal.
  1. Model Number or Basic "MIL-PRF" Series number.
  2. Military "Slash" number.
  3. Timing Range, Fixed: 100 milliseconds to 600 seconds. (See Note 6).
  4. Mounting style and quality level (See Note 7).
Date of issue: 3/06 - 80 - Page 2 of 3