ENGINEERING DATA SHEET FLR300
TIME DELAY RELAY
2 PDT, 2 AMP

APPLICABLE SOCKETS:
S300
S302
Time delay relay (on operate, on release or repeat cycle timer)

Fixed or adjustable timing delay

Contact arrangement 2 PDT
Power supply Direct current

PRINCIPLE TECHNICAL CHARACTERISTICS


Contacts rated at

2 Amps / 28 Vdc
Weight < 0.154lb
Dimensions of case 1.73in x 1.13in x 0.52in max
Tin plated hermetically sealed metal can.
CONTACT ELECTRICAL CHARACTERISTICS
Minimum
operating cycles
Contact rating per
pole and load type
Load Current in Amps
@28Vdc @115Vac/60-400Hz
100,000 cycles
100,000 cycles
500,000 cycles
resistive load
inductive load (L/R=5ms)
low level (30µA/30mV max)
2
0.75
-
0.3
-
-
100 cycles
resistive overload 4 -
NUMBERING SYSTEM
                                        FLR300  -  B   4   A   0.1s   A    1
Basic series designation___________________|       |   |   |     |    |    |
1-Mounting Styles (A,B,C,D,J)______________________|   |   |     |    |    |
2-Terminal Types (1,2,4)_______________________________|   |     |    |    |
3-Types Of Operation (A,B,C)__ ____________________________|     |    |    |
4-Time range (1,2,3,4) or fixed time in s _______________________|    |    |
5-Temperature Range (A,B) ____________________________________________|    |
6-Accuracy (1,2,3) ________________________________________________________|
      
LEACH ® INTERNATIONAL
Solutions for Power Switching and Control

www.leachintl.com
North America
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622 USA

Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
Europe, SA
2 Rue Goethe
57430 Sarralbe
France

Tel: (33) 3 87 97 98 97
Fax: (33) 3 87 97 84 04
Asia-Pacific Ltd.
20/F Shing Hing Commercial Bldg.
21-27 Wing Kut Street
Central, Hong Kong

Tel: (852) 2 191 2886
Fax: (852) 2 389 5803
Date of issue: 6/00 - 75 - Page 1 of 4