GENERAL CHARACTERISTICS
|
FLS300
|
| Temperature range |
| - Code A |
-55° C to +125° C |
| - Code B |
-40° C to +85° C |
| Operating Voltage |
18 to 32 Vdc (AIR norm 2021 E) |
| Recycle Time |
less than or equal to 50 ms |
| Dielectric strength between all pins
connected together and can |
500 V / 50 Hz |
| Insulation resistance at 100 Vdc (same
condition as above) |
greater than or equal to 100 M W |
| Sinusoidal vibration |
20G / 10 to 2000 Hz |
| Shock |
50G / 11 ms |
ACCURACY
|
fixed period |
adjustable period |
|
|
Accuracy resistor Rx to choose |
Code 3 Code 2 Code 1
|
±10% ±5% ±3% |
±10% ±5% ±3% |
5% 100 ppm /° C 2% 100 ppm /° C 1% 50 ppm /°
C |
NOTES
1. Relays with B,C,D mounting and terminal 4 are compatible with socket families S300.
2. Isolation spacer pads for PCB mounting available on request.
3. For other mounting styles or terminal types, please contact the factory.
|
|