ELECTRICAL SPECIFICATION
|
TD-1435
|
| Input (Control) Parameters |
Timing:
a. Operation, Time Delay on
b. Method
c. Range
d. Accuracy
|
Operate
Fixed Period
0.05 to 500 Seconds
±10% [1]
|
| Recycle Time |
10 ms, Max [5] |
Operations: (X1-X2)
a. Input & Control Voltage
b. Operating Current
|
18-32 Vdc
5 mA, Max @ +25° C
|
Transients: MIL-STD-704A, Limit 1
a. Spike Susceptibility
b. Self-Generated Spikes
|
+80 Volts Max
-600 Volts Max
None
|
|
Electromagnetic Interference Per MIL-STD-461A
|
Class 1D [3]
|
|
Power Interrupt
|
1 Millisecond [2]
|
|
| Output (Load) Parameters |
Contact Form
Contact Rating:
Voltage Drop, Maximum
Leakage Current, Maximum
a. at 28 Vdc and 25° C
b. at 28 Vdc and 125° C
|
SPST
250 mA
2 Vdc
1 Microampere
10 Microamperes
|
Dielectric Strength:
a. @ Sea Level, 60 Hz
b. @ 80,000 ft., 60 Hz
|
1000 Vrms [4]
350 Vrms
|
|
Insulation Resistance @ 500 Vdc
|
1000 M W [4]
|
GENERAL CHARACTERISTICS
Ambient Temperatures Range:
a. Operating
b. Non-Operating
|
-55 to +125° C
-55 to +125° C
|
Vibration: a. Sinusoidal
|
10-80 Hz 80-3000 Hz
|
0.06" DA 30 G |
|
b. Random: 50-2000 Hz, MIL-STD-810
|
0.4 G2/Hz |
|
Shock, 0.5 MS, 1/2 Sine, 3 Axis
|
1,100 G
|
|
Acceleration, in any Axis
|
100 G
|
|
Life at Rated Resistive Load; Minimum
|
1,000,000 operations
|
NUMBERING SYSTEM
PCB Mount Flange Mount
TD-1435 - 1001 W TD-1435 - 1001 A
| | | | | |
1 3 4 1 3 4
M83726/20 - 1001 W M83726/20- 1001 A
| | | | | | | |
1 2 3 4 1 2 3 4
|
- Model Number or Basic "MIL-R" Series number.
- Military "Slash" number.
- Timing Range, Fixed: 50 milliseconds to 500 seconds.(See Note 6)
|
- Mounting style and quality level (See Note 7).
W = Printed circuit mountable.
A = Flange mount with solder hook terminal.
|
|