ELECTRICAL SPECIFICATION
|
TDH-1609
|
| Input (Control) Parameters |
Timing:
a. Operation, Time Delay on
b. Method
c. Range
d. Accuracy
|
Operate
Fixed Period
0.05 to 500 Seconds
±10% [1]
|
| Recycle Time |
10 ms, min [5] |
Operations: (X1-X2)
a. Input & Control Voltage
b. Operating Current
|
20-30 Vdc
10 mA, Max @ +25° C
|
Transients: MIL-STD-704A, Limit 1
a. Positive, Transients
b. Spike Susceptibility
c. Self-Generated Spikes
|
+80 Volts Max
±600 Volts Max
None
|
|
Electromagnetic Interference Per MIL-STD-461A
|
Class 1D [3]
|
|
Power Loss
|
1 ms [2]
|
|
| Output (Load) Parameters |
Contact Form
Contact Rating
Voltage Drop, Maximum
Leakage Current, Maximum:
a. at 28 Vdc and 25° C
d. at 28 Vdc and 125° C
|
SPST
150 mA
2 Vdc
1 Microampere
10 Microamperes
|
Dielectric Strength:
a. @ Sea Level, 60 Hz
b. @ 80,000 ft., 60 Hz
|
1000 Vrms [4]
350 Vrms
|
|
Insulation Resistance @ 500 Vdc
|
1000 M W [4]
|
GENERAL CHARACTERISTICS
Ambient Temperatures Range:
a. Operating
b. Non-Operating
|
-55 to +125° C
-55 to +125° C
|
Vibration: a. Sinusoidal
|
|
10-55 Hz
|
0.06" DA |
|
55-500 Hz
|
10 G |
|
500-3000 Hz
|
20 G |
|
b. Random: MIL-STD-810
|
0.2 G2/Hz |
|
Shock, 0.5 MS, 1/2 Sine, 3 Axis
|
1,100 G
|
|
Acceleration, in any Axis
|
100 G
|
|
Life at Rated Resistive Load; Minimum
|
1,000,000 operations
|
NUMBERING SYSTEM
TDH-1609 - 1001 W M83726/24 - 1001 W
| | | | | | |
1 3 4 1 2 3 4
- Model Number or Basic "MIL-PRF" Series number.
- Military "Slash" number.
- Timing Range, Fixed: 100 milliseconds to 500 seconds. (See Note 6).
- Quality level (See Note 7).
|
|