I/O PIN ELECTRICAL SPECIFICATIONS
|
ZE-X9YN
|
POWER ON/RESET
| Normal conditions |
18 to 32 Vdc |
| Operating current at 28 Vdc |
100 mAmp max, contactor "open" |
|
350 mAmp max, contactor "closed" |
CMD
| High level |
Min 7 to 10.5 Vdc |
| Low level |
Min 3 to 7.4 Vdc |
| Input histeresis |
1.3 to 4.3 Vdc |
| Pull-up resistor |
10 K W+/- 1% |
| Input capacitance |
<125nF |
| Input current |
<200 mAmp at 28 Vdc |
TRIP LEVEL PROGRAMMABILITY
| Current status |
Phase A, B, C |
| Frequency PWM output |
666.7 Hz, +/- 3% |
| Low level duty cycle |
25% to 40% |
| High level duty cycle |
60% to 75% |
| Signal amplitude |
7.5 to 16.5 Vdc |
| Rise Time |
20 to 100 msec |
| Output resistance |
4 K W nominal |
LATCH STATUS
| High Level |
>100 K W to 28 Vdc |
| Low Level |
<100 W to DC return |
CONTACTOR STATUS
| Contactor closed |
115/200 Vac, 400 Hz, typical via 47 K W resistor |
| Contactor open |
Open circuit |
CONTROL LOGIC SPECIFICATION
| Undervoltage trip |
Contactor control logic will initiate a trip within 25ms
if 28 VDC supply drops below 20 Vdc while load current is equal to or above 460 Amp +/- 6%.
The contactor will remain in the open state until a reset command sequence is provided.
|
| Over current trip |
Contactor control logic will initiate a trip if load current exceeds the I2t trip curve.
The contactor will remain in the open state until a reset command sequence is provided. |
| Reset command |
The contactor clears, from the latched state, by removing 28 Vdc power (open circuit)
for a period greater than or equal to 250 ms. The contactor resets by removing CMD input
(open circuit) for a period greater than or equal to 5 ms. |
| Undervoltage lockout |
The control logic shall command open and the ELCU shall de-energize within 50 ms of the
28 Vdc power supply dropping to less than 9.5 Vdc. The control logic shall maintain all
functions when the 28 Vdc power supply is between 10 to 18 Vdc.
|
|