COIL CHARACTERISTICS (Vdc)
SERIES ZE-X9YN
Nominal operating voltage 28 Vdc
Pick-up voltage 15 Vdc
Drop-out voltage 1.5 to 7 Vdc
Maximum pick-up time 25 ms
Maximum drop-out time 15 ms
Maximum pick-up current 4 Amp for 1 sec max
Maximum hold current .25 Amp

GENERAL CHARACTERISTICS
Contact Data Main Contacts
-Configuration 3PST NO
-Supply voltage 115/200 Vac
-Continuous current 60 Amp at .85PF
-Rupture current 1600 Amp
-Overload 800 Amp
-Maximum contact bounce 3 ms
-Simultaneous operation 3 ms
-Short circuit current 2200 Amp RMS, once
Electrical life
-At ambient pressure 25,000 operations
-At 45,000 ft 25,000 operations
Mechanical life 100,000 operations
Altitude 45,000 ft
Continuous operating temperature range -15°C to +65°C

NUMBERING SYSTEM
                                               ZE-X2YN - XXX
   Basic series designation_________________________|    |
   Customer configuration________________________________|
      
Date of issue: 01/07 - 45 - Page 2 of 5