COIL CHARACTERISTICS (Vdc)
SERIES Z-X9YN
Nominal operating voltage 28 Vdc
Pick-up voltage 18 Vdc
Drop-out voltage 1.5 to 7 Vdc
Maximum pick-up time 50 ms
Maximum drop-out time 20 ms at 28 Vdc
Maximum pick-up current 4 Amp (shall not trip a 5 Amp circuit breaker)
Maximum hold current at 28 Vdc .27 Amp
Minimum hold voltage 10 Vdc
Coil transient suppression +/- 45 V max

GENERAL CHARACTERISTICS
Contact Data Main Contacts Aux Contacts
-Configuration 3PDT 3X 1PDT
-Supply voltage 115/200 Vac 28 Vdc
-Continuous current 100 Amp at .65PF 5 Amp resistive
-Rupture current 1000 Amp -
-Overload 400 Amp -
-Maximum contact bounce 3 ms 5 ms
-Simultaneous operation 5 ms 5 ms
Electrical life
-At 45,000 ft 25,000 operations
-At ambient pressure 25,000 operations
Mechanical life 100,000 operations
Altitude 45,000 ft
Continuous operating temperature range -15°C to +65°C

NUMBERING SYSTEM
 
                                               Z-X9YN - XXX
   Basic series designation_________________________|    |
   Customer configuration________________________________|
      
Date of issue: 01/07 - 61 - Page 2 of 3