COIL CHARACTERISTICS (Vdc)
|
SERIES WE-X2YN
|
| Nominal operating voltage |
28 Vdc |
| Pick-up voltage |
15 Vdc |
| Drop-out voltage |
1.5 to 9 Vdc |
| Maximum pick-up time |
25 ms |
| Maximum drop-out time |
15 ms |
| Maximum pick-up current |
4 Amp for 1 sec, max |
| Maximum hold current |
.5 Amp |
GENERAL CHARACTERISTICS
| Contact Data |
Main Contacts |
| -Configuration |
3PST NO |
| -Supply voltage |
115/200 Vac |
| -Continuous current |
175 Amp at .75PF |
| -Rupture current |
1600 Amp |
| -Overload |
800 Amp |
| -Maximum contact bounce |
3 ms |
| -Simultaneous operation |
3 ms |
| -Short circuit current |
2200 Amp RMS, 4 times |
| Electrical life |
| -At ambient pressure |
25,000 operations |
| -At 45,000 ft |
25,000 operations |
| Mechanical life |
100,000 operations |
| Insulation resistance |
³ 40 M W at 500 Vrms |
| Dielectric Strength |
| -All circuits to ground |
1500 Vrms |
| -Circuit to circuit to ground and aux contacts |
1250 Vrms |
| Altitude |
45,000 ft |
NUMBERING SYSTEM
WE-X2YN - XXX
Basic series designation_________________________| |
Customer configuration________________________________|
|
|