COIL CHARACTERISTICS (Vdc)
SERIES WE-X2YN
Nominal operating voltage 28 Vdc
Pick-up voltage 15 Vdc
Drop-out voltage 1.5 to 9 Vdc
Maximum pick-up time 25 ms
Maximum drop-out time 15 ms
Maximum pick-up current 4 Amp for 1 sec, max
Maximum hold current .5 Amp

GENERAL CHARACTERISTICS
Contact Data Main Contacts
-Configuration 3PST NO
-Supply voltage 115/200 Vac
-Continuous current 175 Amp at .75PF
-Rupture current 1600 Amp
-Overload 800 Amp
-Maximum contact bounce 3 ms
-Simultaneous operation 3 ms
-Short circuit current 2200 Amp RMS, 4 times
Electrical life
-At ambient pressure 25,000 operations
-At 45,000 ft 25,000 operations
Mechanical life 100,000 operations
Insulation resistance ³ 40 M W at 500 Vrms
Dielectric Strength
-All circuits to ground 1500 Vrms
-Circuit to circuit to ground and aux contacts 1250 Vrms
Altitude 45,000 ft

NUMBERING SYSTEM
 
                                              WE-X2YN - XXX
   Basic series designation_________________________|    |
   Customer configuration________________________________|
      