COIL CHARACTERISTICS (Vdc)
SERIES W-X9YN
Nominal operating voltage 28 Vdc
Pick-up voltage 15 Vdc
Drop-out voltage 1.5 to 10 Vdc
Maximum pick-up time 20 ms at 20 Vdc
Maximum drop-out time 20 ms
Maximum pick-up current 6 Amp
Maximum hold current .8 Amp
Minimum hold voltage 10 Vdc
Coil transient suppression +/- 45 V max

GENERAL CHARACTERISTICS
Contact Data Main Contacts Aux Contacts
 -Configuration 3PST NO 2X 1PST NC, 3X 1PST NO
 -Supply voltage 115/200 Vac 28 Vdc
 -Continuous current 275 Amp at .5PF 100mA; compatible with a 7.5A circuit breaker
 -Rupture current 1600 Amp -
 -Overload 520 Amp -
 -Maximum contact bounce 3 ms 3 ms
 -Simultaneous operation 3 ms 3 ms
Electrical life
 -At ambient pressure 25,000 operations
 -At 45,000 ft 25,000 operations
Mechanical life 100,000 operations
Insulation resistance ³ 40 M W at 500 Vrms
Dielectric Strength
 -All circuits to ground 1500 Vrms
 -Circuit to circuit to ground and aux contacts 1250 Vrms
Altitude 45,000 ft
Continuous operating temperature range -15°C to +65°C

NUMBERING SYSTEM
 
                                               W-X9YN - XXX
   Basic series designation_________________________|    |
   Customer configuration________________________________|
      
Date of issue: 01/07 - 140 - Page 2 of 3