ENGINEERING DATA SHEET SERIES 9213
POWER CONTACTOR
3 PST-DM, 50/100 AMP

    APPLICATION NOTES:
    103G
Hermetically sealed
Balanced armature design
Designed to the
performance standards of
MIL-PRF-6106

PRINCIPLE TECHNICAL CHARACTERISTICS


Contacts rated at

28 Vdc; 115 Vac, 400 Hz, 1Ø 115/200 Vac, 60/400 Hz, 3Ø
Weight 2.7 lb max
Dimensions 4.22in x 4.23in x 4.53in
Special units available upon request

CONTACT ELECTRICAL CHARACTERISTICS
Contact rating per pole
and load type [1]
Load current in Amps
28 Vdc 115 Vac
400 Hz
115/200 Vac
400 Hz 3Ø
WYE OR DELTA
115/200 Vac
60 Hz 3Ø
WYE OR DELTA
440 Vac
60/400 Hz
Resistive
Inductive
Motor [2]
Minimum Current
100
100
100
-
100
100
100
-
100
100
100
-
50
50
50
-
50
-
-
-


  Featuring LEACH© power and control solutions
  www.esterline.com
AMERICAS
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622


Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
EUROPE
2 Rue Goethe
57430 Sarralbe
France


Tel: (33) 3 87 97 31 01
Fax: (33) 3 87 97 96 86
ASIA
Units 602-603 6/F Lakeside 1
No.8 Science Park West Avenue
Phase Two, Hong Kong Science Park
Pak Shek Kok, Tai Po, N.T.
Hong Kong
Tel: (852) 2 191 3830
Fax: (852) 2 389 5803

Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component.
Date of issue: 06/10 - 73 - Page 1 of 3