GENERAL CHARACTERISTICS CONTINUED SERIES W
Release time at nominal voltage (Including bounce), Economizer coil
- DC 25 ms max [7]
- AC 100 ms max
Contact bounce at nominal voltage 4 ms max
Weight 4.50lbs max.
Overload - 115/200 Vac, 400Hz 1800 Amperes
Rupture - 115/200 Vac, 400Hz 2750 Amperes
Altitude 80,000 Feet

NUMBERING SYSTEM
 
                                                    W -  X   0   X
   Relay family_____________________________________|    |   |   |
   1-Mounting Style(A,B,Etc.)____________________________|   |   |
   2-Terminal & Circuit (1,2,3,Etc.)_________________________|   |
   3-Coil Voltage(A,F,N,Y,YN)____________________________________|
      

NOTES
[1] Auxiliary contact rating - see page 5, note [2].
[2] Inductive load life, 20,000 cycles.
 3. Alternate contact configurations and other special models available upon request. Please contact factory.
 4. Terminal strength per para. 3.4.8.2.1 of MIL-R-6106.
[5] Back EMF suppression to 62 volts max.
[6] Economizer coils have a lower resistance primary coil for faster operate time. Once relay operates, the coil switches to a higher resistance for lower power drain. Do not ramp up voltage on these coils.
[7] Greater values for suppressed coils.
 8. This series drawing is for general use only. Please consult factory for special requirements.

Date of issue: 01/07 - 136 - Page 3 of 5