GENERAL CHARACTERISTICS CONTINUED
|
SERIES ZG
|
| Contact bounce at nominal voltage |
4 ms max |
| Weight |
Noted |
| Overload |
1000 Amp @ 115/200 Vac, 400 Hz |
| Rupture |
1400 Amp @ 115/200 Vac, 400 Hz |
| Altitude |
50,000 Feet |
NUMBERING SYSTEM
ZG - X 0 X
Relay family______________________________________| | | |
1-Mounting Style(A,B,Etc.)____________________________| | |
2-Terminal & Circuit(1,2,3,Etc) __________________________| |
3-Coil Voltage(A,B,C,F,N,Y,YN)________________________________|
|
NOTES
[1] Auxiliary contact rating - see page 5, note [2].
[2] Inductive load life, 20,000 cycles.
[3] Ratings are for double break/make terminal type 6.
[4] Alternate contact configurations and other special models available upon request. Please contact factory.
[5] Back EMF suppression to 62 Volts Max.
[6] Suitable for transfer between unsynchronized AC power sources at rating shown.
[7] 200 Amps resistive, 25,000 cycles only, terminal style 6.
[8] Economizer coils have a lower resistance primary coil for faster operate time. Once relay operates, the coil switches to a higher resistance for lower power drain. Do not ramp up voltage on these coils.
9. This series drawing is for general use only. Please consult factory for special requirements.
|
|