GENERAL CHARACTERISTICS CONTINUED
SERIES ZG
Contact bounce at nominal voltage 4 ms max
Weight Noted
Overload 1000 Amp @ 115/200 Vac, 400 Hz
Rupture 1400 Amp @ 115/200 Vac, 400 Hz
Altitude 50,000 Feet

NUMBERING SYSTEM
 
                                                    ZG - X   0   X
   Relay family______________________________________|   |   |   |
   1-Mounting Style(A,B,Etc.)____________________________|   |   |
   2-Terminal & Circuit(1,2,3,Etc) __________________________|   |
   3-Coil Voltage(A,B,C,F,N,Y,YN)________________________________|
      

NOTES
[1] Auxiliary contact rating - see page 5, note [2].
[2] Inductive load life, 20,000 cycles.
[3] Ratings are for double break/make terminal type 6.
[4] Alternate contact configurations and other special models available upon request. Please contact factory.
[5] Back EMF suppression to 62 Volts Max.
[6] Suitable for transfer between unsynchronized AC power sources at rating shown.
[7] 200 Amps resistive, 25,000 cycles only, terminal style 6.
[8] Economizer coils have a lower resistance primary coil for faster operate time. Once relay operates, the coil switches to a higher resistance for lower power drain. Do not ramp up voltage on these coils.
 9. This series drawing is for general use only. Please consult factory for special requirements.
Date of issue: 01/07 - 95 - Page 3 of 5