ENGINEERING DATA SHEET SERIES H,HD,HP,HT,HDT,HPT
CONTACTOR
60 AMP

Balanced-Force Design
Hermetically sealed
Designed to the
performance standards of
MIL-PRF-6106

PRINCIPLE TECHNICAL CHARACTERISTICS


Contacts rated at

28 Vdc and 115 Vac, 400 Hz, 1 Ø and 115/200 Vac, 400Hz, 3Ø
Weight 14.0 Oz.
Special units available upon request, including models with auxiliary contacts. Optional Ground Fault Protection (GFP) feature available.
Contact factory for information on MIL-qualified part numbers.

CONTACT ELECTRICAL CHARACTERISTICS
Contact rating per pole
and load type [1]
Load current in Amps
28 Vdc 115 Vac
400 Hz
115/200 Vac
400 Hz
115 Vac
60 Hz
DELTA
Resistive
Inductive [2]
Motor
Intermediate current
Load transfer [3]
50
20
20
10
-
50 [5]
20 [5]
-
-
-
60
60
-
-
12.5/60
65 [5]
65 [5]
-
-
12.5/60
60
60
40
15
12.5/60
30
30
30
-
-