ENGINEERING DATA SHEET SERIES 9124
CONTACTOR
3 PST, 50 AMP

Balanced armature design
Hermetically sealed
Contact arrangement 3 PST
Designed to the
performance standards of
MIL-PRF-6106

PRINCIPLE TECHNICAL CHARACTERISTICS


Contacts rated at

28 Vdc; 115 Vac, 400 Hz, 1 Ø 115/200 Vac, 400 Hz, 3 Ø
Weight 1.25 lb max
Dimensions 3.31in x 3.73in x 2.44in
Special units available upon request, including models with auxiliary contacts.

CONTACT ELECTRICAL CHARACTERISTICS
Contact rating per pole
and load type [1]
Load current in Amps
28 Vdc 115 Vac
400 Hz
115/200 Vac
400 Hz,
115 Vac
60 Hz [5]
440 Vac
60 Hz [5]
DELTA
Resistive
Inductive [6]
Motor
Intermediate current
50
50
50
5
50
50
50
5
50
50
50
5
30
30
15
15
15
15
12
-