ENGINEERING DATA SHEET WN460
RELAY - NONLATCH
4 PDT, 2 AMP

    APPLICATION NOTE:
    001
Non polarized, non latching hermetically sealed relay.
Contact arrangement 4 PDT
Coil supply Direct current
Compatible with MIL-R-39016/39

PRINCIPLE TECHNICAL CHARACTERISTICS


Contacts rated at

2 Amp / 28Vdc
Weight 34 grams max
Dimensions of case
without mounting brackets
25.65mm x 15.5m x 25.4mm max
Hermetically sealed corrosion protected metal can.

CONTACT ELECTRICAL CHARACTERISTICS
Minimum
operating cycles
Contact rating per
pole and load type
Load Current in Amps
@28Vdc @115Vac/60-400Hz

100,000 cycles
100,000 cycles


100,000 cycles
100,000 cycles
100,000 cycles

1,000,000 cycles
Relay case grounded:
resistive load
inductive load (0.2H)

Relay case not grounded:
resistive load
inductive load (0.2H)
lamp load

low level (50ľA/50mV max)

2
0.25


-
0.5
0.25

-

0.25
-


1
-
-

-
100 cycles
resistive overload 4 -
Esterline-Leach International
  www.leachintl.com
North America
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622 USA

Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
Europe, SA
2 Rue Goethe
57430 Sarralbe
France

Tel: (33) 3 87 97 98 97
Fax: (33) 3 87 97 84 04
Asia-Pacific Ltd.
20/F Shing Hing Commercial Bldg.
21-27 Wing Kut Street
Central, Hong Kong

Tel: (852) 2 191 2886
Fax: (852) 2 389 5803
Data sheets are for initial product selection and comparison. Contact Leach International prior to choosing a component.
Date of issue: 3/06 - 41 - Page 1 of 4