COIL CHARACTERISTICS (Vdc) SERIES K
CODE A B C M N [4] R [4] V [4]
Nominal operating voltage 28 12 6 48 28 12 6
Maximum operating voltage 29 14.5 7.3 50 29 14.5 7.3
Maximum pickup voltage
- Cold coil at +125° C 18 9 4.5 36 18 9 4.5
- During high temp test at +125° C 19.8 9.9 5 38 19.8 9.9 5
- During continuous current test at +125° C 22.5 11.25 5.7 42 22.5 11.25 5.7
Maximum drop-out voltage 7 4.5 2.5 14 7 4.5 2.5
Coil resistance W ±10% +25° C, except types "C" and "V" +20%, -10% 290 70 18 890 290 70 18
GENERAL CHARACTERISTICS
Temperature range -70°C to +125°C
Minimum operating cycles (life) at rated load 100,000
Minimum operating cycles (life) at 25% rated load 400,000
Dielectric strength at sea level - All circuits to ground and circuit to circuit 1250 Vrms
Dielectric strength at sea level - Coil to ground 1000 Vrms
Dielectric strength at altitude 80,000 ft 500 Vrms [5]
Insulation resistance - Initial (500 Vdc) 100 M W min
Insulation resistance - After environmental tests (500 Vdc) 50 M W min
Sinusoidal vibration (A and D mounting) 0.12DA / 10 to 70 Hz
30G / 70 to 3000 Hz
Sinusoidal vibration (G and J mounting) 0.12DA / 10 to 57 Hz
20G /57 to 3000 Hz
Random vibration
- Applicable specification MIL-STD-202
- Method 214
- Test condition - A and D mounting 1G (0.4G2/Hz, 50 to 2000 Hz)
- Test condition - G and J mounting 1E (0.2G2/Hz, 50 to 2000 Hz)
- Duration 15 minutes each plane
Shock (A, D and W mounting) 200G / 6 ms
Shock (G and J mounting) 100G / 6 ms
Maximum contact opening time under vibration and shock 10 µs
Operate time at nominal voltage@25°C 15 ms max
Release time at nominal voltage@25°C 15 ms max
Contact make bounce at nominal voltage@25°C 1 ms max
Contact release break bounce at nominal voltage@25°C 0.1 ms max [6]
Weight maximum 0.156lb
Unless otherwise noted, the specified temperature range applies to all relay characteristics.
Date of issue: 9/07 - 126 - Page 2 of 4