ENGINEERING DATA SHEET
|
SERIES KDL
RELAY - LATCHING
3 PST/NO +AUX, 25 AMP
|
|
|
|
| Magnetic latch operation |
| All welded construction |
| Contact arrangement |
3 PST configuration with 1 PDT, 2 AMP auxiliary contacts in one inch cube |
Designed to the performance standards of |
MIL-PRF-6106 |
PRINCIPLE TECHNICAL CHARACTERISTICS |
Contacts rated at |
28 Vdc; 115 Vac and 115/200 Vac, 400 Hz, 3Ø |
| Weight |
0.188lb max |
| Dimensions |
1.01in x 1.01in x 1.00in |
Hermetically sealed, corrosion resistant metal can.
Detail specifications and ordering data appear on the following pages. |
| Contact factory for information on MIL-qualified part numbers. |
|
CONTACT ELECTRICAL CHARACTERISTICS
Contact rating per pole and load type [1] |
Load current in Amps |
| @28 Vdc |
@115 Vac 400 Hz |
@115/200 Vac, 400 Hz, 3Ø |
@115/200 Vac, 60 Hz, 3Ø [10] |
Resistive [2]
Inductive [3]
Motor
Lamp
Overload
Rupture
|
25
12
10
5
50
60
|
25
15
10
5
80
100
|
25
15
10
5
80
100
|
2.5
2.5
2
1
N/A
N/A
|
Contact rating of auxiliary contacts
at 28 Vdc or 115 Vac 400 Hz |
Resistive 2 Amp |
Inductive 1 Amp |
Lamp 0.5 Amp |
|