NOTES SERIES KDA
[1] Standard Intermediate current test applicable.
[2] For full rated load, max. temp. and altitude use no. 12 wire or larger.
    Relays to be mounted to limit mounting bracket temp. to 135° C.
[3] DC inductive load 10,000 cycles. AC inductive load 20,000 cycles.
[4] Dielectric of auxiliary contact gap after life tests: 750 Vrms.
[5] 500 Vrms with silicone gasket compressed, 350 Vrms all other conditions.
6. Reference military specification: MIL-PRF-6106, and MIL-PRF-6106/13.
7. Special models available: dry circuit, established reliability testing, etc.
[8] Applicable to power contacts only.
[9] 60 Hz load life, 10,000 cycles.
[10] Time current relay characteristics per MIL-PRF-6106.
[11] Temperature range:
   Non-operating -62°C to +95°C
   Operating -54°C to +71°C

NUMBERING SYSTEM
                                                    KDA- A   4   F
   Basic series designation__________________________|   |   |   |
   1-Mounting Style (A,D,E,J)____________________________|   |   |
   2-Terminal Types (1,2,4) [1]______________________________|   |
   3-Coil Voltage see coil characteristics (E,F,J,K or T)________|
      

MOUNTING STYLES
Date of issue: 01/07 - 169 - Page 3 of 4