NOTES SERIES KD
[1] Standard Intermediate current test applicable.
[2] For full rated load max. temp. and altitude use no. 12 wire or larger.
    Solder hook relays to be mounted to limit mounting bracket temp. to 160° C.
[3] DC inductive load 10,000 cycles, AC inductive load 20,000 cycles.
[4] Dielectric of auxiliary contact gap after life tests: 750 Vrms, 60 Hz.
[5] 500 Vrms with silicone gasket compressed, 350 Vrms all other conditions.
6. Applicable military specification: MIL-PRF-6106 and M6106/13.
7. Special models available: Dry circuit, high reliability testing, etc.
[8] "N, R & V" coils have back EMF suppression to 42 volts maximum.
[9] Applies to "N, R & V" coils and main contacts only.
[10] 60 Hz load life, 10,000 cycles.
11. Time current relay characteristics per MIL-PRF-6106.
12. Relay will not operate, but will not be damaged by application of reverse polarity to coil.

NUMBERING SYSTEM
      
                                                       
                                                    KD - A   4   A
   Basic series designation__________________________|   |   |   |
   1-Mounting Style (A,D,J,W)____________________________|   |   |
   2-Terminal Types (1,2,4)__________________________________|   |
   3-Coil Voltage see coil characteristics (A,B,C,M,N,R or V)____|
      

MOUNTING STYLES
Date of issue: 3/06 - 165 - Page 3 of 4