[1] Standard Intermediate current test applicable.
[2] For full rated load, max. temp. and altitude use no. 12 wire or larger.
Solder hook relays to be mounted to limit mounting bracket temp. to 160° C.
[3] DC inductive load 10,000 cycles, AC inductive load 20,000 cycles.
[4] 500 Vrms with silicone gasket compressed, 350 Vrms all other conditions.
5. Applicable military specification: MIL-PRF-83536.
6. Special models available: Dry circuit, high reliability testing, etc.
[7] "N, R & V" coils have back EMF suppression to - 42 volts maximum.
[8] Applies to "N, R & V" coils only.
[9] 60 Hz load life, 10,000 cycles.
10. Time current relay characteristics per MIL-PRF-6106.
11. Relay will not operate, but will not be damaged by application of reverse polarity to coil.
|
NUMBERING SYSTEM
KC - A 4 A
Basic series designation__________________________| | | |
1-Mounting Style (A,D,J,W)____________________________| | |
2-Terminal Types (1,2,4)__________________________________| |
3-Coil Voltage see coil characteristics (A,B,C,M,N,R or V)____|
|
MOUNTING STYLES
|