COIL CHARACTERISTICS (Vdc) SERIES JCL
CODE A B C M N [7] R [7] V [7]
Nominal operating voltage 28 12 6 48 28 12 6
Maximum operating voltage 29 14.5 7.3 50 29 14.5 7.3
Maximum pickup voltage
- Cold coil at +125° C 18 9 4.5 36 18 9 4.5
- During high temp test at +125° C 19.8 9.9 5 38 19.8 9.9 5
- During continuous current test at +125° C 22.5 11.25 5.7 42 22.5 11.25 5.7
Coil resistance W ±10% +25° C except types "C" & "V" +20%, -10% 600 150 38 1600 600 150 38

GENERAL CHARACTERISTICS
Temperature range -70°C to +125°C
Minimum operating cycles (life) at rated load (resistive and motor) 50,000 [5]
Minimum operating cycles (life) at 25% rated (resistive) load 200,000
Dielectric strength at sea level
- All circuits to ground and circuit to circuit 1250 Vrms
- Coil to ground and coil to coil 1000 Vrms
Dielectric strength at altitude 80,000 ft 500 Vrms [2]
Insulation resistance
- Initial (500 Vdc) 100 M W min
- After environmental tests (500 Vdc) 50 M W min
Sinusoidal vibration (A, D, J and W mounting) 0.12DA / 10 to 70 Hz
30G / 70 to 3000 Hz
Random vibration
- Applicable specification MIL-STD-202
- Method 214
- Test condition - A, D, J and W mounting 1G (0.4G2/Hz, 50 to 2000 Hz)
- Duration 15 minutes each plane
Shock (A, D and J mounting) 200G / 6 ms
Shock (G mounting) 100G / 6 ms
Maximum contact opening time under vibration and shock 10 µs
Operate time at nominal voltage (either coil)@25°C 10 ms max
Contact make bounce at nominal voltage@25°C 1 ms max
Weight maximum 45 grams
Unless otherwise noted, the specified temperature range applies to all relay characteristics.
Date of issue: 3/06 - 135 - Page 2 of 4