[1] Standard Intermediate current test applicable.
[2] 500 Vrms with silicone gasket compressed, 350 Vrms all other conditions.
3. Applicable military specification: MIL-PRF-6106 and M6106/19.
[4] Special models available dry circuit, established reliability testing, etc.
[5] Inductive load life, 20,000 cycles for AC 10,000 cycles DC.
[6] For full rated load, max temp and altitude use no. 12 wire or larger, solder hook relays to be mounted to limit
mounting bracket temperature to 160° C for JC series and 135° C for JCA series.
[7] "N" coil has back EMF suppression to 42 volts maximum.
[8] Applicable to JCA, Applicable to JC with "N" coil only.
[9] 60 Hz load life, 10,000 cycles.
10. Time current relay characteristics per MIL-PRF-6106.
11. JC series: Relay will not operate, but will not be damaged by application of reverse polarity to coil.
|
NUMBERING SYSTEM
JC OR JCA - A 2 A
Basic series designation__________________________| | | |
1-Mounting Style (A,D or J)_______________________________| | |
2-Terminal Types (1,2,4,7)____________________________________| |
3-Coil Voltage see coil characteristics (A,B,C,E,F,J,K,M or N)____|
|
MOUNTING STYLES
|