ENGINEERING DATA SHEET SERIES JC AND JCA
RELAY - NONLATCH
1 PDT, 25 AMP

All welded construction
Contact arrangement 1 PDT
Qualified to MIL-PRF-6106

PRINCIPLE TECHNICAL CHARACTERISTICS


Contacts rated at

28 Vdc; 115 Vac, 400 Hz, 1Ø
Weight 0.10lb max
Dimensions 1.01in x .51in x 1.00in (JC)
1.01in x .51in x 1.12in (JCA)
Special models available upon request.
Hermetically sealed, corrosion resistant metal can.

CONTACT ELECTRICAL CHARACTERISTICS
Contact rating per pole
and load type [1]
Load current in Amps
@28 Vdc @115 Vac, 400 Hz, 1Ø @115/200 Vac, 60 Hz, 1Ø [9]
Resistive [6]
Inductive [5]
Motor
Lamp
Overload
Rupture
25
12
10
4
50
60
25
15
10
4
80
100
2.5
2.5
2
1
N/A
N/A
Esterline-Leach International
  www.leachintl.com
North America
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622 USA

Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
Europe, SA
2 Rue Goethe
57430 Sarralbe
France

Tel: (33) 3 87 97 98 97
Fax: (33) 3 87 97 84 04
Asia-Pacific Ltd.
20/F Shing Hing Commercial Bldg.
21-27 Wing Kut Street
Central, Hong Kong

Tel: (852) 2 191 2886
Fax: (852) 2 389 5803
Data sheets are for initial product selection and comparison. Contact Leach International prior to choosing a component.
Date of issue: 3/06 - 146 - Page 1 of 4