COIL CHARACTERISTICS (Vdc) F600
CODE B A N E V
Nominal operating voltage 12 28 28 48 110
Maximum operating voltage at +125° C 14 29 29 50 125
Maximum pickup voltage at +125° C 10 19.8 19.8 34.1 75
Guaranteed drop-out voltage at -65° C 0.5 1.5 1.5 2 5
Coil resistance in W ±10% at +25° C 40 210 210 620 3200
Exported spikes (Vdc) N/A N/A -42 N/A N/A

GENERAL CHARACTERISTICS
Temperature range -65°C to +125°C
Dielectric strength at sea level
- Contacts to ground and between contacts 1250 Vrms / 50 Hz
- Coil to ground 1000 Vrms / 50 Hz
Dielectric strength at altitude 25,000 m (all points) 350 Vrms / 50 Hz
Initial insulation resistance at 500 Vdc 100 M W min
Sinusoidal vibration 30 G / 75 to 3000 Hz
Shock 50 G / 6 ms
Maximum contact opening time under vibration and shock 10 µs
Operate time at nominal voltage 15 ms max
Release time 10 ms max
Bounce time 1 ms max
Contact voltage drop at nominal current
- initial value 150 mV max
- after life 175 mV max
Date of issue: 01/07 - 106 - Page 2 of 4