ENGINEERING DATA SHEET F600
RELAY - NONLATCH
6 PDT, 10 AMP

Polarized, non latching hermetically sealed relay
Contact arrangement 6 PDT
Coil supply Direct current
Designed to the
performance standards of
M 83536/25,26
CECC16101-020
CECC16303-806

PRINCIPLE TECHNICAL CHARACTERISTICS


Contacts rated at

10 Amps / 28 Vdc OR 115 Vac - 400 Hz
Weight 95 grams max
Dimensions of case 26mm x 25.7mm x 37.7mm max
Hermetically sealed, corrosion protected metal can.
Intrinsically safe relay.

CONTACT ELECTRICAL CHARACTERISTICS
Minimum
operating cycles
Contact rating per
pole and load type
Load Current in Amps
@28 Vdc @115 Vac, 400 Hz @115/200 Vac, 400 Hz, 3Ø
100,000 cycles
20,000 cycles
100,000 cycles
100,000 cycles
resistive load
inductive load (L/R=5ms)
motor load
lamp load
10
8
4
2
10
8
4
2
10
8
4
2
50 cycles
resistive overload 40 60
400,000 cycles
at 25% rated resistive load