| Temperature range |
-70°C to +125°C |
| Minimum operating cycles (life) at
rated load |
50,000 |
| Minimum operating cycles (life) at 25%
rated load |
200,000 |
| Dielectric strength at sea
level |
| - All circuits to ground and circuit
to circuit |
1000 Vrms |
| - Coil to ground |
1000 Vrms |
| Dielectric strength at altitude 80,000 ft |
500 Vrms [6] |
| Insulation resistance - Initial (500 Vdc) |
100 M W min |
| Insulation resistance - After environmental tests (500 Vdc) |
50 M W min |
| Sinusoidal vibration (A, D and J mounting) |
0.12DA / 10 to 70 Hz
30G / 70 to 3000 Hz |
| Sinusoidal vibration (G mounting) |
0.12DA / 10 to 57 Hz
20G /57 to 3000 Hz |
| Random vibration - Applicable specification |
MIL-STD-202 |
| Random vibration - Method |
214 |
| Random vibration - Test condition - A, D and J mounting |
1G (0.4G2/Hz, 50 to 2000 Hz) |
| Random vibration - Test condition - E and G mounting (E in Track) |
1E (0.2G2/Hz, 50 to 2000 Hz) |
| Random vibration - Duration |
15 minutes each plane |
| Shock (A, D and J mounting) |
200G / 6 ms |
| Shock (G mounting) |
100G / 6 ms |
| Maximum contact opening time under
vibration and shock |
10 µs |
| Operate time at nominal voltage@25°C |
6 ms max |
| Release time at nominal voltage@25°C |
6 ms max |
| Contact make bounce at nominal voltage@25°C |
1 ms max |
| Contact release break bounce at nominal voltage@25°C |
0.1 ms max [7] |
| Weight maximum |
0.034lb |