[1] Standard Intermediate current test applicable; relay can also switch low level load while switching any of the
other rated loads on adjacent contacts.
[2] Inductive load life, 20,000 cycles.
[3] Low level endurance test: contact load of 10 to 50 millivolt, 10 to 50 microamp, 100 W max. contact
resistance.
[4] Refer to MIL-PRF-6106 for details.
[5] "N" "R" & "V" coils have back EMF suppression to 42 volts maximum.
[6] 500 Vrms with silicone rubber gasket compressed, 250 Vrms all other conditions.
[7] Suppressed coils limited to +85° C.
8. Reference MIL-PRF-6106.
9. Relay will not be damaged, but may transfer with application of reverse polarity to coil.
|
NUMBERING SYSTEM
YL A 1 A Basic series designation__________________________| | | | 1-Mounting Style (A,D,G,J)____________________________| | | 2-Terminal Types (1,2,4)__________________________________| | 3-Coil Voltage, see coil characteristics (A,B,C,N,R,V)________|
|
MOUNTING STYLES
|