NOTES SERIES XL
[1] Standard Intermediate current test applicable; relay can also switch low level loads while switching any of the
    other rated loads on adjacent contacts.
[2] Inductive load life, 20,000 cycles.
[3] Low level endurance test: contact load of 10 to 50 millivolt, 10 to 50 microamp, 100 Ohm max. contact
    resistance.
[4] Refer to MIL-PRF-83536 for details.
[5] "N" "R" & "V" coils have back EMF suppression to 42 volts maximum.
[6] 500 Vrms with silicone rubber gasket compressed, 250 Vrms all other conditions.
[7] "N", "R" & "V" coils derated to 85° C.
8. Reference MIL-PRF-83536/1,2,3,4.
9. Relay will not be damaged, but may transfer with application of reverse polarity to coil.

NUMBERING SYSTEM
                                                  XL  A   1   A
Basic series designation__________________________| | | |
1-Mounting Style (A,D,G,J)____________________________| | |
2-Terminal Types (1,2,4)__________________________________| |
3-Coil Voltage, see coil characteristics (A,B,C,N,R,V)________|

MOUNTING STYLES
Date of issue: 9/07 - 47 - Page 3 of 4