ENGINEERING DATA SHEET SERIES X
RELAY - NONLATCH
2 PDT, LOW LEVEL TO 5 AMP

Contact arrangement 2 PDT
Qualified to MIL-PRF-6106

PRINCIPLE TECHNICAL CHARACTERISTICS


Contacts rated at

Low level, 28 Vdc and 115/200 Vac, 400Hz 3Ø, case grounded
Weight 0.034lb max
Dimensions .41in x .81in x .64in
Special models available upon request.

Hermetically sealed, corrosion resistant metal can.

CONTACT ELECTRICAL CHARACTERISTICS
Contact rating per pole
and load type [1]
Load current in Amps
@28 Vdc @115 Vac, 400 Hz, 1Ø @115/200 Vac, 400 Hz, 3Ø
Resistive
Inductive [2]
Motor
Lamp
Overload
Rupture
Low level [3]
Time current characteristics [4]
5
3
2
1
20
25
-
-
5
5
3
1
30
40
-
-
5
5
3
-
30
40
-
-
Esterline-Leach International
  www.leachintl.com
North America
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622 USA

Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
Europe, SA
2 Rue Goethe
57430 Sarralbe
France

Tel: (33) 3 87 97 98 97
Fax: (33) 3 87 97 84 04
Asia-Pacific Ltd.
20/F Shing Hing Commercial Bldg.
21-27 Wing Kut Street
Central, Hong Kong

Tel: (852) 2 191 2886
Fax: (852) 2 389 5803
Data sheets are for initial product selection and comparison. Contact Leach International prior to choosing a component.
Date of issue: 9/07 - 53 - Page 1 of 4