ENGINEERING DATA SHEET F250
RELAY - NONLATCH
2 PDT, 2 AMP

Non polarized, non latching hermetically sealed relay
Contact arrangement 2 PDT
Coil supply Direct current
Designed to the performance standards of MIL-PRF-39016/6
Qualified to CECC16101-014
BS CECC16101-021
Contact types
per CECC1610-021
Contacts with reduced service life for resistive loads (contact types I, II, III) -- Code 01; contacts with reduced service life at low level resistive loads -- Code 02

PRINCIPLE TECHNICAL CHARACTERISTICS


Contacts rated at

2 Amps / 28 Vdc
Weight less than 11 grams
Dimensions of case 20.6mm x 10.4mm x 10.5mm
Hermetically sealed, corrosion protected metal can.

CONTACT ELECTRICAL CHARACTERISTICS
Minimum
operating cycles
Contact rating per
pole and load type
Load Current in Amps
@28Vdc @115Vac/60-400Hz
100,000 cycles
100,000 cycles
100,000 cycles
resistive load
inductive load (L/R=5ms)
lamp load
2
0.75
-
0.3
-
-
100 cycles
resistive overload 4 -
400,000 cycles
at 25% rated load